Firefighters battle structure fire on Trails End Rd, Edmond OK
Firefighters are actively fighting a structure fire near Lucifer Trail in Edmond. Crews are cutting ventilation holes in the roof to manage heat and smoke inside the building. They have opened multiple ventilation points, including on the Delta and Bravo sides, and are using fans to improve airflow and reduce smoke. The fire is being controlled with no active flames visible inside at some points, and efforts to cool the structure are underway. No personal names or identifying details are included.
Audio|Source: Edmond Police and Fire
06:15
Transcript:
00:00
Command Rescue 5
00:04
Rescue 5 You can go ahead and work on the cable on the Alpha side here
00:11
See if I can get it opened up
00:17
Command Engine 5 are you all out, part 3
00:27
Have you all exit part three?
00:33
That's permanent engine five, figure, par three. We've done a face-to-face with the engine one.
00:38
Clear, go ahead and recycle your bottles and go back on deck.
00:44
Signal 20, 208.5 at the Lucifer trail.
00:49
Okay.
00:50
Figure one, any instructions?
00:56
Command clear, Angie 1 entering part 4.
01:03
Command engine 5, engine 5. Do you guys have all the red equipment up there with you on deck?
01:10
The red equipment is right by the front door.
01:20
Command Clear.
01:22
You guys go ahead and get a fan and just said that the front door note started yet, but will this be prepared for some ventilation?
01:34
Any of the class back?
01:46
Come I, enjoy it with Ken.
01:51
We're up top of stairs.
01:53
We're on the Delta side, attic,
01:55
heat,
01:57
and you see a roof ride, and see the active fire.
02:00
We've got a lot of speed track up here, I think if we could cut it in the table where you're trying to put it over here.
02:09
Command clear on needing to cut the gable. Engine 4 is working on that. They'll be on the Delta side cutting it. Just advise if you want the Bravo side started and if you want Sam started.
02:28
Probably somewhere in the middle for an entrance on air, and then we were on a nozzle, so if anything left off, we're on a nozzle and we're on a nozzle. Right now we've got a lot of James poke, no active fire that we can see on a fit.
02:50
Can you repeat your traffic, please?
02:55
That's affirmative.
02:57
I think if we get another hole on the other side of the opposite of the Delta, not midway through the roof,
03:03
I think we don't get some smoke and clean.
03:12
You'd rather that you want another line inside on Delta?
03:20
Negative. Just two ventilation holes.
03:24
One on Delta,
03:25
one if we can, towards the northern house for interest of air for the exit of Delta.
03:37
To man clear.
03:38
We'll get the one cut on Delta and we'll look at it and try to get a second vent hole.
03:44
Tensions for command.
03:46
The delta gable hole has been cut.
03:50
Command clear.
03:51
Delta gable hole cut.
03:54
Come back to command and let's assess if we can find another spot.
04:03
Thank you, morning, command.
04:05
Mr. Sam, the front door on.
04:12
Man Clear stands at the front door, not on currently.
04:20
Agent wants your hands?
04:24
Command.
04:28
If there's good pressure coming out to Delta side, we can turn on the fan for a second and people push it out, we're on the line.
04:39
Command Clear, we'll start the fan.
04:42
I'm considering opening the garage doors, if you feel like that help you, you'll get a windward side there as well.
04:51
We did not see any attic access in the garage.
04:54
I think this will be too broke up in between the garage and the Delta Side.
05:00
Command Clear, do you think opening the doors up to get the ventilation started will help you?
05:06
Maybe so, and even somebody on a fan, be able to turn it up, if something else off we can do that as well.
05:16
To Manclare, we've started the fan, we've got the ventilation hole opened on the delta side at the peak of the roof.
05:24
I'll have a crew open that garage doors.
05:30
We're already getting some lift and starting to cool a little bit as well.
05:37
Command clear, cooling slightly.
05:43
Command to Engine 1, I'm going to go ahead and have them cut an additional vent hole. This one will be on the Bravo side at the peak of the roof as well,
05:53
to try to get some cross ventilation in there.
05:59
Clear.
06:04
If we're having good success with that, maybe a second fan,
06:10
we're seeing moving a smoke pretty good and it's definitely cooling pretty quick.
Disclaimer:
This transcript was automatically generated and may contain inaccuracies. Please verify the information independently.
Location mentioned:
Trails End Rd, Edmond, OK 73034
This shows a Google Street View of the area near the location, which might not be the exact address.
Correct
Incorrect